zeigen 120 Ergebnisse für "ceiling fan dc motor"
-
40W 1.7A Wechselstrom-Spaltpol-Ventilatormotor, Wohnküchen-Ventilatormotor
40W 1.7A AC Shaded Pole Fan Motor , Residential Kitchen Fan Motor Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-40-2 40W 115 60 1.7 2 3000 YZJ-45-2 45W 120 60 2.4 2 2800 YZJ-50-2 50W 115 60 2.5 2 2800 YZJ-60-2 60W 120 60 1.6 2 2800 YZJ-5-4 ...
-
Spaltpol-Ventilatormotor-Belüftungs-Ventilatormotor mit 3000 U/min asynchroner
3000 RPM Asynchronous Shaded Pole Fan Motor Ventilation Fan Motor Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-50-2 50W 115 60 2.5 2 2800 YZJ-60-2 60W 120 60 1.6 2 2800 YZJ-5-4 5W 115 60 0.58 4 1550 YZJ-10-4 10W 115 60 0.70 4 1350 YZJ-15-4 ...
-
umschaltbarer Ventilatormotor der kleinen Erschütterungs-60W für Gas-Ofen-Abwasser-Pumpe
60W Small Vibration Reversible Fan Motor For Gas Furnace / Sewage Pump Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-60-2 60W 120 60 1.6 2 2800 YZJ-5-4 5W 115 60 0.58 4 1550 YZJ-10-4 10W 115 60 0.70 4 1350 YZJ-15-4 15W 230 60 0.23 4 1550 ...
-
Energiesparender Spaltpol-Ventilatormotor für USA-Markt-Ausgangsbelüftung
Energy Saving Shaded Pole Fan Motor For Usa Market Home Ventilation Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-5-4 5W 115 60 0.58 4 1550 YZJ-10-4 10W 115 60 0.70 4 1350 YZJ-15-4 15W 230 60 0.23 4 1550 YZJ-20-4 20W 115 60 1.2 4 1450 YZJ...
-
3000 U/min 10W 115V 3,3" Spaltpol-Ventilatormotor-hoher Anlaufmoment
3000 RPM 10W 115V 3.3" Shaded Pole Fan Motors High Starting Torque Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-10-4 10W 115 60 0.70 4 1350 YZJ-15-4 15W 230 60 0.23 4 1550 YZJ-20-4 20W 115 60 1.2 4 1450 YZJ-25-4 25W 115 60 1.55 4 1400 YZJ...
-
Spaltpol-Ventilatormotor der Vernickelungs-60Hz mit CER Bescheinigung
60Hz 1.55A Nickel Plating Shaded Pole Fan Motor With UL / CE Certification Technical Parameters:ModelOutput power/WVoltage/VFrequency/HzRated current/APoleSpeed/RPMYZJ-25-425W115601.5541400YZJ-30-430W230600.7541450YZJ-30-430W115601.4541500YZJ-35-435W115601.641500YZJ-40-440W115602.041500YZJ-45...
-
Kundengebundener asynchroner Spaltpolmotor-Badezimmer-Ventilatormotor 35W
Customized Asynchronous Shaded Pole Motor , Bathroom Fan Motor Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-35-4 35W 115 60 1.6 4 1500 YZJ-40-4 40W 115 60 2.0 4 1500 YZJ-45-4 45W 115 60 2.2 4 1450 YZJ-55-4 55W 230 60 0.6 4 1500 Note: ...
-
4 Pole-Spaltpol-Ventilatormotor
115V 40W Air Conditioner Spare Parts Shaded Pole Fan Motor used as air ventilation Technical Parameters: Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM YZJ-40-4 40W 115 60 2.0 4 1500 YZJ-45-4 45W 115 60 2.2 4 1450 YZJ-55-4 55W 230 60 0.6 4 1500 Note: Listed are ...
-
Elektrophoretischer Beschichtungs-Einschließungs-Spaltpol-Ventilatormotor für Flügelradgebläse
Electrophoretic Coating Enclosure Shaded Pole Fan Motor For Fan Blower Technical Parameters: Note: Listed are representative motors, only for reference, dimensions can be customized according to customer requirements. Model Output power /W Voltage /V Frequency /Hz Rated current /A Pole Speed /RPM ...
-
4 Geschwindigkeits-Innenventilatormotor für Klimaanlage, HVAC-Ventilatormotor
4 Speed Indoor Fan Motor For Air Conditioning Unit , HVAC Fan Motor Technical Parameters Below are representative motors, only for reference, dimensions and parameters can be customized according to customer requirements, OEM/ODM service offered. Model Number Voltage /V Frequency /Hz Output Power /W ...
-
Doppelter Motor der Wellen-Klimaanlagen-FCU
Double Shaft Air Conditioning FCU Motor Motor Application: Fan coil motor is used in various fan coil unit, including indoor fan coil unit of central air conditioner, kinds of high static pressure air conditioner fan coil, axial and cross flow fan. Technical Parameters: Note: Listed are representati...
-
Einheits-Ventilatormotor im Freien, Klimaanlagen-Ventilatormotor lärmarm
Outdoor Unit Fan Motor , Air Conditioning Fan Motor Low Noise Motor Application: Split air conditioner outdoor unit and fresh air ventilation system Technical Parameters: Model Number Output Power /W Voltage /V Frequency /Hz Rated Speed /RPM Rated Current /A YDK95-20-6 20 220-240 50/60 830 0.25 ...